Aquatec’s concrete and fibreglass pumping stations form an essential part of water and wastewater infrastructure in our communities.

Aquatec is regularly consulted by regulatory and industry bodies, water authorities and councils across Australiasia to provide pumping stations for complex infrastructure requirements.

Aquatec pump stations along with our end-to-end processes have set new standards in environmental risk management, safety and serviceability.

Our custom approach to control systems delivers a consistently high level of operational integrity.

Select a product

Concrete Pump Stations

Structurally engineered to deliver on individual project specifications, operational requirements and site conditions.

Select

Concrete Pump Stations

Aquatec concrete pump stations are structurally engineered to deliver on individual project specifications, operational requirements and site conditions.

Select
Fibreglass Pump Stations

Fibreglass Pump Stations

Manufactured as a one-piece vessel to exact project specifications, allowing for a seamless installation process.

Select

Fibreglass Pump Stations

Aquatec’s fibreglass pump stations are manufactured as a one-piece vessel to exact project specifications, allowing for a seamless installation process.

Select

A commitment to product integrity for 30 years

Engineered with S50 (50 MPa) concrete to exceed Australian standards, structural integrity continues to be central to our precast pump station designs.

Product integrity is vital to us. We reach this through our focus on perfection from design through to commissioning. We tailor each concrete pump station to perfectly suit the individual specifications of each project, drawing on our years of experience to make this a seamless process for you.

Concrete Pump Station

Specifications

Internal Diameter1200 x 1200mm
Integral ValveN/A
Increment Size300-600mm
Max Depth (m)5m
Capacity Per Extra Metre (Litre)1450L
Internal Diameter1800mm
Integral Valve1200 x 1200mm
Increment Size315-1000mm
Max Depth (m)15m
Capacity Per Extra Metre (Litre)2500L
Internal Diameter2250mm
Integral Valve1500 x 1500mm
Increment Size500-2500mm
Max Depth (m)15m
Capacity Per Extra Metre (Litre)3950L
Internal Diameter3200mm
Integral Valve2200 x 1800mm
Increment Size500-2500mm
Max Depth (m)15m
Capacity Per Extra Metre (Litre)8000L

A seamless solution for exact specifications

Aquatec fibreglass pump stations are manufactured as a one-piece vessel to precise project specifications, and delivered on site as a complete unit for easy installation.

Each fibreglass pump station is engineered to withstand internal and external loadings across all ground conditions.

For more than 30 years, our commitment to product innovation has remained central to the development of our fiberglass pump stations. We recognise that by taking a holistic approach to design and delivery, we can ensure a seamless experience regardless of a project’s specifications and site conditions.

Specifications

Diameter (mm)1250mm
Depth (Metres)1-10m
Volume (Litres)1,200-12,000L
Diameter (mm)1500mm
Depth (Metres)1-10m
Volume (Litres)1,700-17,000L
Diameter (mm)1800mm
Depth (Metres)1-10m
Volume (Litres)2,500-25,000L
Diameter (mm)2000mm
Depth (Metres)1-10m
Volume (Litres)3,100-31,000L
Diameter (mm)2500mm
Depth (Metres)1-10m
Volume (Litres)4,900-49,000L
Diameter (mm)3000mm
Depth (Metres)1-10m
Volume (Litres)7,000-70,000L
Diameter (mm)3500mm
Depth (Metres)1-10m
Volume (Litres)9,600-96,000L
Diameter (mm)4000mm
Depth (Metres)1-10m
Volume (Litres)12,500-125,000L
Diameter (mm)4500mm
Depth (Metres)1-10m
Volume (Litres)15,900-160,000L
Diameter (mm)5000mm
Depth (Metres)1-10m
Volume (Litres)19,600-196,000L

One-piece cover slab
This innovative slab houses the lids, switch board cubicle, vent stack and reduced pressure zone (RPZ) assembly, eliminating additional onsite concrete works.

Meeting all WHS standards
Our pump station access meets every water authority and council requirement, designed along with our fall arrest barriers.

Valve chamber options
Our integral valve chambers prevent differential ground settlement, while our external valve chambers suit large pipeworks.

Protection against corrosive gases
Our internal chamber coatings and H2S-resistant high-density polyethylene (HDPE) liners lock into all concrete surfaces.

Mould form construction
Delivers an impervious finish with a minimum concrete strength of 50 MPa for consistent cover.

One-piece cover slab
This innovative slab houses the lids, switch board cubicle, vent stack and reduced pressure zone (RPZ) assembly, eliminating additional onsite concrete works.

Meeting all WHS standards
Our pump station access meets every water authority and council requirement, designed along with our fall arrest barriers.

Valve chamber options
Our integral valve chambers prevent differential ground settlement, while our external valve chambers suit large pipeworks.

Protection against corrosive gases
Our internal chamber coatings and H2S-resistant high-density polyethylene (HDPE) liners lock into all concrete surfaces.

Mould form construction
Delivers an impervious finish with a minimum concrete strength of 50 MPa for consistent cover.

Fully compliant
Built to Australian and British standards, certified by a registered composite engineer.

Designed to last
The unique chamber is mould formed as one piece for strength, durability and functionality.

Integral valve chambers
These eliminate the line-up of separate valve chambers and prevent differential ground settlement.

Benchmark quality
The filament is wound through a computerised winder and manufactured with the highest-grade resins.

External access
The pump station is designed to provide maximum protection for maintenance personnel.

Fully compliant
Built to Australian and British standards, certified by a registered composite engineer.

Designed to last
The unique chamber is mould formed as one piece for strength, durability and functionality.

Integral valve chambers
These eliminate the line-up of separate valve chambers and prevent differential ground settlement.

Benchmark quality
The filament is wound through a computerised winder and manufactured with the highest-grade resins.

External access
The pump station is designed to provide maximum protection for maintenance personnel.

00 What we do for you

By taking a holistic approach to our water and wastewater solutions, we guarantee a perfect end-to-end solution with no hidden costs.

01 Design

Our design engineers work closely with you, analysing all aspects of the project, providing a complete set of drawings/hydraulic calculations for construction, and consulting with relevant water authorities.

02 Procurement

Our procurement schedule maps out all components of your asset, including any critical time components to ensure they align with your construction program.

03 Construction Program

A dedicated project manager establishes a construction program that works for you and ensures timelines and key milestones are met.

04 Pre-Start Meeting

Upon approval of design drawings, our site construction managers go through every step of the process with your team, from delivery of the structural components to commissioning and handover.

05 Craning & Excavation

Our detailed craning and excavation brief includes lifting methods, weights, the excavation size and backfill requirements to ensure the integrity of your asset.

06 Pre-Assembly

We pre-assemble all relevant mechanical components at our facility under controlled environments to ensure a smooth build on-site and seamless installation with quality assurance.

07 Civil Installation

Our installation training allows the civil contractor to be familiar with the process, backed by a civil installation guide with a step-by-step breakdown of what will be experienced on site and how we can help.

08 Mechanical Fitout

Under the direction of our lead field technician, our mechanical fitters install valves, pipework, pumps, guiderails, flow meters, landings and ladders, and connect pipework as per our offer.

09 Factory Acceptance Test

All equipment is thoroughly tested prior to delivery with a Factory Acceptance Test (FAT) which can be witnessed by relevant council or water authority personnel.

10 Electrical Fitout

Our electrical team connects the pump cables and level controls, places the electrical switchboard on the slab, and supervises all approvals of documentation with relevant power authorities.

11 On-Site Pre-Test

Prior to final commissioning, our technicians perform a thorough test of all mechanical components, pumps and flow rate measurements for accuracy, efficiency and compliance.

12 Final Commissioning

A complete re-run of the pre-tests includes all stakeholders and relevant water authorities, who connect their SCADA for final testing and approval. Our operation and maintenance training includes crosschecks for compliance and final sign-off.

13 Ongoing Support

We not only back the integrity of our system for the long term, our after-sales support provides peace of mind through refresher training and technical support.

Aquatec Pump Stations

Aquatec works closely with clients to deliver expert knowledge across flows, friction loss, static lift, atmosphere, pipe sizing and air locks by taking into consideration development size, type of loadings and point of discharge.

Related Products

Aquatec offers a wide range of related products which work seamlessly together to enhance your project.

Water & Wastewater Reuse

Our water and wastewater reuse systems reduce demand on potable water supplies for municipal, industrial and private projects.

View More

Storage Vessels

Custom designed for your project’s specifications, our fibreglass storage vessels are structurally engineered to handle critical inflows.

View More

Pressure Sewer

Aquatec pressure sewer systems are one of the most economical and environmentally friendly sewerage systems available.

View More

Get in Touch

Have a question for us or wish to discuss a project? Send us some information using the form our 4 step contact form.

1300 088 555

Headquarters

2 Provincial Crescent,
Shepparton, VIC 3630

Melbourne CBD

Level 5 (Morgan Group)
356 Collins Street,
Melbourne, VIC 3000

Sydney

Lvl 1, Suite F, Octagon Building
110 George Street
Parramatta NSW 2150

Brisbane

47 Moreton Street,
Heathwood, QLD 4110

Adelaide

844 South Road,
Edwardstown, SA 5039